The Humidifier Solenoid Valve – A Mutual Frustration

The Humidifier Solenoid Valve – A Common Frustration

J. Paige Freeland; Marketing Managing director, General Filters, Inc.

The Humidifier Solenoid Valve – A Common Frustration - GeneralAire Indoor Air Quality Blog - 1137-17_Solenoid_ValveA common frustration amid homeowners who installed and use a whole firm humidifier in their HVAC arrangement is a malfunctioning solenoid valve.

A solenoid valve is a control unit that uses electricity to automate the opening and closing of an orifice in the valve trunk, allowing, preventing, or redirecting the flow of h2o, gas, or other medium.  It is fabricated up of three main parts: the solenoid body, the electromagnetically inductive ringlet, and internal components (stem, plunger, and spring).

Solenoid valves are used in washing machines, dishwashers, ice makers, refrigerators, vending machines, sprinklers, and many other systems requiring water flow.  Equally such, whole-house humidifiers utilise a solenoid valve to control the amount of water flowing to the humidifier; specifically, an electromagnetic 2-way (with 2 ports; inlet and outlet) solenoid valve.

Why do they fail? Can they be cleaned? Or exercise they need to be replaced?

At that place are several reasons a solenoid valve may stop working properly.

  1. The most mutual reason solenoid valves fail is that dirt or other contaminants get lodged in the valve seat, preventing the solenoid from opening or closing properly.


Solution:  A simple cleaning may exist all that is needed.

2. Improper voltages, electrical malfunction, or loss of power tin also cause:

  1. Improper opening or endmost.
  2. Corrosion.
  3. Burnt-out coils.
  4. Freezing in the open, closed or partially-opened position information technology was concluding operating in.

Solution:  C heck that the manufacturer-recommended voltage to the humidifier and valve are correct.

  1. Excessive fluid force per unit area differentials betwixt the inlet and outlet sides of a valve can crusade internal valve components to buzz or ballyhoo during operation.

Solution:  Check fluid pressure and make adjustments as necessary.

  1. A leaky valve usually means that the solenoid is stuck open up or partially open up. This tin be caused by a number of problems, simply inevitably creates leakage of liquid.  Causes included degraded O-rings, a plunger valve that does non close completely, cracks in the plunger valve seat, or internal dirt particle build up.

    Solution: The solenoid valve needs to be replaced.

The Humidifier Solenoid Valve – A Common Frustration - GeneralAire Indoor Air Quality Blog - Solenoid_Valve_Parts

Make clean vs. replace

When debris collects in the valve seat of the solenoid valve body, it tin can simply be cleaned and returned to the humidifier.  Corrosion can be removed by soaking in vinegar and water.  As with any mechanical apparatus, proper and proactive maintenance and care of a solenoid valve can extend product life and ensure predictable operation.  On average, a solenoid valve should last between 1 and three years.

Does h2o supply affair?

It can, yes.  Water with high sediment levels can clog a solenoid valve more than quickly; notwithstanding, installing a filter in the water supply line prior to the solenoid valve will reduce the number of particles reaching the valve.

Where in that location's water, there's maintenance; whether you lot take a decorative fountain, a bathtub with jets, a faucet aerator, or a humidifier.

Your humidifier provides a valuable service in providing healthier indoor air quality.  Maintaining it will ensure it will practise and then for years to come.

Folio: ane 2 3 iv 5 6 7 8 9 10 xi

How To Repair Kip Silenoid,

Source: https://www.generalfilters.com/blog/The-Humidifier-Solenoid-Valve--A-Common-Frustration_AE253.html

Posted by: knoxwhadn1945.blogspot.com

0 Response to "How To Repair Kip Silenoid"

Post a Comment

Iklan Atas Artikel

Iklan Tengah Artikel 1

Iklan Tengah Artikel 2

Iklan Bawah Artikel